Setup guide · Teltonika + DUT-E S7

Connect a wireless DUT-E S7 fuel level sensor to a Teltonika FMB120

Pair a Bluetooth DUT-E S7 fuel level sensor with a Teltonika FMB120 tracker, send fuel level, frequency, temperature and error codes to the server, and set up the sensors in Wialon. Covers both DUT-E S7 types, 0113 and 0107.

wagencontrol.eu/compatibility/teltonika/fmb120-dut-e-s7/

Tracker
Teltonika FMB120
Sensor
DUT-E S7 wireless fuel level sensor, type 0113 or 0107
Interface
Bluetooth (S7), no wiring between sensor and tracker
Tracker firmware
03.27.01 Rev:00 or later (type 0107)
Configurator
Teltonika Configurator 1.6.4 B.3.27 R2 or later
Sensors per tracker
Up to 4 DUT-E S7 (type 0107)
Server in this guide
Wialon Hosting (any server that reads Teltonika IO elements works)

Before you start: which DUT-E S7 do you have?

The setup depends on the sensor's firmware type, printed in its serial number: numbers starting 0113 or 0107. Type 0107 is the current one: it supports up to four sensors per tracker and uses the presets built into the Teltonika Configurator. Read the DUT-E S7 manual first and switch the sensor to operating mode.

Type 0113

1. Find the sensor's MAC address

The tracker finds the sensor by its Bluetooth MAC address, which is the sensor's serial number converted from decimal to hexadecimal.

  1. Read the serial number on the sensor body, e.g. 113 001 300 014.
  2. Convert it to hexadecimal, e.g. with a calculator in Programmer mode: 1A 4F 67 00 2E.
  3. The MAC address has 6 bytes, so add leading zeros: 00 1A 4F 67 00 2E.
  4. Alternatively, scan for the sensor with the Fuel Tanks Monitor app for Android: it shows the MAC address directly.
DUT-E S7 sensor body with the serial number highlighted
Figure 1. The serial number on the sensor body.
Calculator in Programmer mode converting 113 001 300 014 to hexadecimal 1A 4F67 002E
Figure 2. Decimal to hexadecimal in a calculator's Programmer mode.
Fuel Tanks Monitor Android app listing two DUT-E S7 sensors with their MAC addresses
Figure 3. The Fuel Tanks Monitor app shows each sensor's MAC address.

2. Set up the tracker

  1. Insert a SIM card into the FMB120 and power it up.
  2. In the Teltonika Configurator, enter the SIM operator's APN and the server domain and port.
  3. Set the data protocol to Codec 8 Extended.
Teltonika Configurator GPRS settings: APN and server domain and port
Figure 4. GPRS settings: APN and server address.
Teltonika Configurator System settings with Codec 8 Extended selected
Figure 5. Data protocol: Codec 8 Extended.

3. Pair the sensor

  1. Place the sensor near the tracker and run a Bluetooth search (Discover BLE).
  2. Find your sensor in the list by the MAC address from step 1 and enter it in the sensor's settings.
  3. Set up which sensor values the tracker reads (frequency, temperature, error mask, level, volume).
Bluetooth 4.0 settings with the Discover BLE button
Figure 6. Search for sensors.
Discovered BLE devices list with the sensor's MAC address entered in the settings
Figure 7. Pick the sensor by its MAC address.
BLE sensor parameter table in the Teltonika Configurator
Figure 8. Sensor parameters read by the tracker.

4. Choose what goes to the server

On the I/O tab, set the priority of each value to Low so the tracker sends it to the server:

IO elementValueUnit
BLE Temperature 1Sensor temperature°C
BLE Fuel Frequency 1Output frequency (fuel level)Hz
Custom3Error code mask (DTCs)–
Custom4Fuel level (reserve)mm
Custom5Fuel volumeL
Teltonika Configurator I/O list with BLE Temperature 1, BLE Fuel Frequency 1 and Custom values set to Low
Figure 9. Send the values to the server by setting them to Low.

5. Set up the sensors in Wialon

Register the tracker in Wialon Hosting with its IMEI. The raw values arrive as IO parameters; create sensors with these formulas:

SensorWialon parameterUnit
Temperatureio_25*const10°C
Frequencyio_306*const0.001Hz
Error mask (DTCs)io_464 (decimal)–
Fuel levelio_465*const0.1mm
Fuel volumeio_466*const0.1L
Wialon unit properties with Teltonika FMB120 as device type
Figure 10. Register the FMB120 in Wialon.
Wialon messages showing raw IO parameters from the tracker
Figure 11. Raw data on the server.
Wialon sensors list: temperature, frequency, DTCs, fuel level, fuel volume
Figure 12. The five sensors in Wialon.
Wialon sensor properties for fuel level in millimetres
Figure 13. Fuel level sensor.
Wialon sensor properties for fuel volume in litres
Figure 14. Fuel volume sensor.
Wialon table with temperature, frequency, DTCs, fuel level and fuel volume over time
Figure 15. Check: all values arrive on the server.

Type 0107

1. Find the sensor's MAC address

As for type 0113: convert the serial number from decimal to hexadecimal, e.g. 107 001 300 025 → 18 E9C6 4439, and add leading zeros to make 6 bytes.

Calculator converting 107 001 300 025 to hexadecimal 18 E9C6 4439
Figure 16. Serial number to MAC address.

2. Set up the tracker

Use FMB120 firmware 03.27.01 Rev:00 or later and Configurator 1.6.4 B.3.27 R2 or later. Insert the SIM card and power the tracker.

  1. Enter the SIM operator's APN and the server domain and port.
  2. Set the data protocol to Codec 8 Extended.
Teltonika Configurator GPRS and server settings
Figure 17. GPRS and server settings.
Codec 8 Extended selected in the System settings
Figure 18. Data protocol: Codec 8 Extended.

3. Pair the sensors

  1. Place the sensors near the tracker and press Discover BLE.
  2. In the list of discovered devices, find the sensor by its MAC address and enter it in the MAC field of the sensor slot.
  3. In the sensor table, press the add button and choose the DUT-E S7 preset from the list: the Configurator fills in the parameters.
  4. Repeat for up to four sensors: the settings are the same, only the MAC address changes.
Bluetooth settings with Discover BLE highlighted
Figure 19. Search for sensors.
Discovered BLE devices with the DUT-E S7 address
Figure 20. Discovered devices.
MAC address entered in the sensor settings
Figure 21. Enter the MAC address.
Preset selection list in the Teltonika Configurator with the DUT-E S7 preset
Figure 22. Choose the DUT-E S7 preset.
Sensor parameter table filled in by the preset
Figure 23. Parameters filled in by the preset.

The preset reads these values:

ParameterValue
NonePGN 63277
Fuel FrequencyOutput frequency in Hz (fuel level)
TemperatureSensor temperature, °C
Custom1–Custom3Lateral, longitudinal and vertical acceleration (reserved: current firmware sends 65535)
Custom4Error code mask (DTCs)

4. Choose what goes to the server

On the I/O tab, set BLE Temperature 1, BLE Fuel Frequency 1 and BLE 1 Custom4 (error mask) to Low.

I/O list with BLE Temperature 1, BLE 1 Custom4 and BLE Fuel Frequency 1 set to Low
Figure 24. Values sent to the server.

5. Set up the sensors on the server

Register the tracker on your telematics server. In Wialon, create a temperature sensor, a fuel level sensor and an error-mask sensor:

SensorWialon parameter
Temperatureio_25*const10
Fuel levelio_306*const0.001 (frequency), converted to litres by the calibration table
Error mask (DTCs)io_465
Raw messages on the server with io_25, io_306 and io_465
Figure 25. Raw data on the server.
Wialon unit sensors: temperature, fuel, DTCs mask
Figure 26. Sensors in Wialon.
Temperature sensor properties
Figure 27. Temperature sensor.
Fuel level sensor properties with parameter io_306*const0.001
Figure 28. Fuel level sensor.

6. Calibrate

Enter the calibration table: sensor frequency against fuel volume, measured while filling the tank in known portions. Wialon then reports litres.

Wialon calculation table with frequency X values and volume Y values
Figure 29. Calibration table: frequency → litres.
DTCs mask sensor properties
Figure 30. Error-mask sensor.
Wialon report with temperature, fuel and DTCs mask values over time
Figure 31. Check: temperature, fuel and error mask on the server.

Last updated 26 November 2026.

Setting up Teltonika FMB120 + DUT-E S7?

Send us your tracker firmware, the server you use and a screenshot of the settings. An engineer checks the setup and helps with the calibration.

Ask an engineer